HYSUCA - 122

USE
The absorbent resistant with the high quality special compound for the pressure resistance/proof works such as: tunnel, underground storey, water tank, irrigational works, hydroelectricity, etc ...

QUALITY STANDARD
These specifications are defined in Quality Assurance & Testing centre 3

  Characteristics

Test
method

Test result

Comparison

Without admixture

With admixture

Depth of water penetration At pressure 0,7MPa (= 7atm)

mm 

DIN 1048

110 

35 

214% decrease

Expansion of mortar stored in water

ASTM C 1038-95

0,007 

0,014 

100% increase

Pullout force at 28 – day ages

kN 

ASTM C 900-99

33,3 

39,8 

19,5% increase

Compressive strength of mortar specimens

MPa 

TCVN 6016:1995

40,5 

45,2 

11,6% increase

Compressive strength of concrete specimens

MPa 

TCVN 3118:1993

27,1 

30,5 

12,5% increase


TEST REPORT OF
QUALITY ASSURANCE AND TESTING CENTRE 3

   Test report
    Concrete specimens report

PRODUCTS’ ADVANTAGES
  The absorbent resistant special compound for the pressure resistance/proof works
  Cement structure with the stretchiness in permit , thanks to increase adherence
    force as the absorbent resistant processing for the works.
  Increase solidity of the structures; enhance adhesiveness with materials and steel rods.
  Consolidate intensity of construction works making them stronger
  Speed up execution progress, casing would be removed after 10 days